Autobahn Python enforces maxMessagePayloadSize against the compressed WebSocket frame length before permessage-deflate inflation, then delivers the inflated message to application callbacks without a second size check. A client frame that is only 22 compressed bytes can inflate to 4096 bytes and reach onMessage even when the application configured a 128-byte message limit, defeating the resource boundary the option is meant to provide.
Autobahn|Python before 20.12.3 allows redirect header injection.
Stay updated with the latest patches and releases. Plan your sofware desisgn. Avoid common known vulnerabilities fixed by the open source community
Latest patch release: 0.18.2
Latest minor release: --
Latest major release: 26.7.1
Maintain your licence declarations and avoid unwanted licences to protect your IP the way you intended.
MIT - MIT License